Learn More. In stock. SKU I understand that the use of this product is strictly reserved for health professionals. Add to Cart Loading Optional Accessories. Shop Now. Optional Patient Interrupt Switch. Selecting Channel. Preparing Patient. Editing Ultrasound from Home Screen. Using the Optional Patient Interrupt Switch. Editing Waveform Parameters. Accessing Patient Data Card.
Setting Intensity. Selecting Clinical Resources Library. Entering User Protocol Name. Selecting User Protocol to Delete. Setting Modality Intensity. Saving to Patient Data Card. Removing Lead Wires and Accessories.
Releasing Ribbon Cable. Positioning Therapy System and Module. Connecting Ribbon Cable. Setting Therapy System onto Module. Attaching the Lanyard. Installing Lead Wires and Accessories. Installing Front Access Panel. Removing Screws Securing Module. Disconnecting Ribbon Cable at Module. Storing and Securing Ribbon Cable. Connecting Mains Power. Preparing the Therapy System Cart. Removing System from Therapy System Cart. Charging Temperature.
It contains general information on the operation, precautionary practices, and maintenance information. In order to maximize use, efficiency, and the life of the system, please read this manual thoroughly and become familiar with the controls, as well as the accessories before operating the system.
Specifications put forth in this manual were in effect at the time of publication. However, owing to Chattanooga Group's policy of continual improvement, changes to these specifications may be made at any time without obligation on the part of Chattanooga Group.
Before administering any treatment to a patient, the users of this equipment should read, understand and follow the information contained in this manual for each mode of treatment available, as well as the indications, contraindications, warnings and precautions.
Consult other resources for additional information regarding the application of electrotherapy and ultrasound. Other optional modality modules are available for separate purchase and may be installed by the end user. Stay current with the latest clinical developments in the field of electrotherapy and ultrasound. Observe all applicable precautionary measures for treatment. Keep informed of appropriate indications and contraindications for the use of electrotherapy and ultrasound.
This equipment is to be used only under the prescription and supervision of a licensed practitioner. Any use of editorial, pictorial, or layout composition of this publication without express written consent from Chattanooga Group of Encore Medical, L. This publication was written, illustrated, and prepared for distribution by Chattanooga Group of Encore Medical, L.
The precautionary instructions found in this section and throughout this manual are indicated by specific symbols. Understand these symbols and their definitions before operating this equipment. The definition of these symbols are as follows:. These Notes are helpful information to aid in the particular area or function being described. Know the limitations and hazards associated with using any electrical stimulation or ultrasound device.
Observe the precautionary and operational decals placed on the unit. Also, determine that the treatment time control does actually terminate ultrasonic power output when the timer reaches zero. Inappropriate handling of the Ultrasound Applicator may adversely affect its characteristics. Ingress of water or liquids could cause malfunction of internal components of the system and therefore create a risk of injury to the patient.
However, there is no guarantee that interference will not occur in a particular installation. Harmful interference to other devices can be determined by turning this equipment on and off. Try to correct the interference using one or more of the following: reorient or relocate the receiving device, increase the separation between the equipment, connect the equipment to an outlet on a.
Federal Law restricts these devices to sale by, or on the order of, a physician or licensed practitioner. This device should be used only under the continued supervision of a physician or licensed practitioner.
Potential electromagnetic or other interference could occur to this or to the other equipment. Try to minimize this interference by not using other equipment in conjunction with it.
This includes headache. Errors and Warnings in these categories indicate an internal problem with the system that must be tested by Chattanooga Group or a Field Service Technician certified by Chattanooga Group before any further operation or use of the system. Use of a system that indicates an Error or Warning in. Consult other resources for additional information regarding the application of Electrotherapy and Ultrasound.
Electrodes in contact with each other could result in improper stimulation or skin burns. Severe spasm of the laryngeal and pharyngeal muscles may occur and the contractions may be strong enough to close the airway or cause difficulty in breathing. Improper application may result in patient injury. If any question arises as to the proper electrode size, consult a licensed practitioner prior to therapy session. Electrical current of this magnitude must not flow through the thorax because it may cause a cardiac arrhythmia.
Energy from diathermy shortwave, microwave, ultrasound, and laser can be transferred through the implanted neurostimulation system, can cause tissue damage, and can result in severe injury or death. In the event of battery cell rupture or leakage, handle Battery Module wearing neoprene or natural rubber gloves.
Contents of a ruptured or leaking battery can cause respiratory irritation. Hypersensitivity to nickel can cause allergic pulmonary asthma. Should an individual cell from a battery become disassembled, spontaneous combustion of the negative electrode is possible.
There can be a delay between exposure to air and spontaneous combustion. Never attempt to charge the Battery Module on any other charging mechanism. Doing so can increase the individual cell temperature and cause cell rupture or leakage. Never short circuit the battery. The battery may explode, ignite, leak or get hot causing serious personal injury. The irritation can usually be reduced by using an alternative conductive medium or an alternative electrode placement.
Application of therapeutic deep heat for the treatment of selected sub-chronic and chronic medical conditions such as:.
Additional precautions should be used when ultrasound is used on patients with the following conditions:. Ultrasound Applicator- 5 cm 2 Standard. Front Access Panel See Page Below are the definitions for all of the symbols used in the Intelect Legend XT hardware and software. Study and learn these symbols before any operation of the system. Below are the definitions for all of the unique terminology used throughout this manual. Study these and become familiar with these terms for ease of system operation and familiarization with the components and control functionality of the Intelect Legend XT Therapy System.
Some of these terms and definitions refer to a specific button or control on the system. Short duration and rectangular pulse shape can provide very strong contractions but very comfortable stimulation. The currents have a slightly different frequency. The total current amplitude is the sum of the two currents at any point in the tissue where they interfere. Vector rotation will change the pattern of stimulation in the tissue volume. Increasing the current in one direction between one pair of electrode will stimulate more fibers lying parallel to the current path.
Mainly use for pain gate control. Whirlpool effect. Clinical usageEasier to apply Maybe be more effective and comfortable in muscle stimulation Greater stimulation remains superficially to treatment. The waveform is monophasic current flows in one direction only.
Slow twitch or fast twitch muscle re-innervation or re-education.